3M Air Monitors are simple and effective devices that collect certain airborne contaminants using the scientific principle of diffusion. They meet or exceed 25% accuracy at a 95% confidence level for many workplace contaminants. (18 months shelf life)
Features/Benefits
Simple and convenient
There are no batteries, hoses, pumps or equipment to calibrate.
Easy to use
Just clip the monitor to shirt lapel, collars, or pocket.
Versatile
3M monitors can also be used for area monitoring, if sufficient air flow exists.
Product support
3M provides reference information needed to use the monitors.
Analysis options
3M monitors can be analyzed in the lab of your choice or returned to 3M for analysis.
Confidence
3M's manufacturing operation is ISO 9002 certified and our testing facilities are accredited by the American Industrial Hygiene Association.
Comfort
3M monitors are small and lightweight and will not interfere with employee activities. |
 |
 |
 |
 |
 |
|
| Compound List |
†Acetone (2) (c)
Acetonitrile (2) (c)
Acrylonitrile (8)
Allyl Alcohol (8)
Amyl Acetate (8)
n-Amyl Alcohol
s-Amyl Alcohol
Benzene (8)
Benzyl Cholride (8)
Bromoform (8)
I-Bromopropane (m)
n-Butyl Acetate (8)
s-Butyl Acetate (8)
t-Butyl Acetate (8)
Butyl Acetate (8)
n-Butyl Alcohol (8)
s-Butyl Alcohol (8)
t-Butyl Alcohol (8)
Butyl Cellosolve (8)
Butyl Glysidyl Ether (8)
p-tert Butyl Toluene (8)
Camphor (8)
Carbon Tetrachloride (8)
Cellosolve (8)
Cellosolve Acetate (8)
Chlorobenzene (8)
Chloroform (8)
0-Chlorostyrene(8)
o-Chlorotoluene (8)
Cumene (8)
Cyclohexane (6)
Cyclohexanol (8) |
Cyclohexanone (8)
Cyclohexene (8)
n-Decane
Diacetone Alcohol (8)
0-Dichlorobenzene (8)
p-Dichlorobenzene (8)
Diisobutyl Ketone (DIBK) (8)
p-Dioxane (8)
Enflurane (8)
Epichlorohydrin (8)
Ethyl Acetate (6)
Ethyl Acrylate (8)
Ethyl Benzene (8)
Ethylene Chlorohydrin (8)
Ethylene Dichloride (EDC) (8)
Ethyl Ether (4) (c)
Furfural (8)
Halothane (8)
n-Heptane (8)
n-Hexane (8)
iso-Amyl Acetate (8)
iso-Butyl alcohol (8)
Isofulrane (Forane)
Isopar G
Isophorone (8)
Isopropyl Acetate (7)
Isopropyl Alcohol (m) (c)
Mesitylene (8)
Mesityl Oxide (8)
Methyl Acrylate (8)
Methyl t-Butyl Ether (MTBE (8)
Methyl Butyl Ketone (MBK) (8) |
Methyl Cellosolve (8)
Methyl Cellosolve Acetate (8)
Methylene Chloride (m)(3530 only)
†Methyl Ethyl Ketone (MEK) (8)
Methyl Isobutyl Ketone (MIBK) (8)
Methyl Methacrylate (8)
Methyl Propyl Ketone (8)
Naptha (VM&P)(8)
n-Octane (8)
Perchloroethylene (8)
Phenyl Ether (8)
n-Propyl Acetate (8)
n-Propyl Alcohol (8)
Propylene Dichloride (8)
Propylene Glycol Mono Methyl
Ether (8)
Proplene Glycol Mono Methyl
Ether Acetate
Stoddard Solvent (8)
Styrene (8)
1,1,2,2-Tetrachloroethane (8)
Tetrahydrofuran (8)
Toluene (8)
1,1,1-Trichloroethane (Methyl Chloroform)(m)
Trichloroethylene (8)
1,1,1-Trichloro-1,2,2,-trifluoroethane (1)(c)
†Vinyl Acetate (8)
Vinyl Toluene (8)
Xylene (8)
Total Hydrocarbons as n-Hexane |
|
 |
 |
 |
 |
 |
 |
 |
| Organic Vapor Monitors |
 |
Formaldehyde Monitors |
 |
 |
Brand: 3M
Model No: 3500, 3510
Packing: 10 each/case 5 each/case |
 |
 |
Brand: 3M
Model No: 3720, 3721
Packing: 5 each/case |
 |
- Single charcoal sorbent wafer for easy collection of organic vapors. Analysis by gas chromatography
- 3M 3500 Monitors only
- 3M 3510 Monitors includes 3M analysis for up to 3 compounds per monitor
|
 |
- Monitors personnel or work areas in health care, laboratories, and in the chemical, pulp/paper, foundry and textile industries. Analysis procedure is available on request
- 3M 3720 Monitors include 3M analysis
- 3M 3721 Monitors only
|
 |
 |
 |
 |
 |
 |
| Organic Vapor Monitors with Back-up |
 |
Ethylene Oxide Monitors |
 |
 |
Brand: 3M
Model No: 3520, 3530
Packing: 5 each/case |
 |
 |
Brand: 3M
Model No: 3550, 3551
Packing: 5 each/case |
 |
- Primary and back-up sorbent pads for sampling demanding environments. Especially suited for monitoring compounds like vinyl chloride, acrylonitrile, butadiene and methylene chloride for which activated carbon shows limited capacity
- 3M 3520 Monitors only
- 3M 3530 Monitors included 3M analysis for up to 3 compounds per monitor
|
 |
- Design for sampling personnel or work in the pharmaceutical, health care and chemical industries. Analysis procedure is available on request
- 3M 3550 Monitors include 3M analysis
- 3M 3551 Monitors only
|
 |
 |
 |
 |
 |
 |
| Kwik-Draw Detector Tube Deluxe Pump |
 |
Orion Multigas Detector |
 |
 |
Brand: MSA
Model No: 487500
Packing: 1 set/case
 |
 |
 |
Brand: MSA
Model No: 10025931
Packing: 1 set/case |
 |
- Used with MSA assortment of detector tubes to spot-test atmosphere for a wide range of toxic substances
- Designed for one-hand operation and consistent delivery of a sample draw volume of 100 milliliters (ml)
- Deluxe pump comes with remote sampling adapter, carry pouch and end-of-stroke indicator
- List of detector tube industry sets available
|
 |
- Low cost, reliable and easy-to-use portable instruments for detecting the presence of O2, H2S, CO and combustible gas
- Feature MSA long-life 20L combustible sensor
- One-button calibration
- Long-life battery
- Carbon-filled nylon case
- Tough, durable construction to withstand roughest handling and toughest environments
- Large, easy-to-read display
- Approved by UL and cUL for use in Class 1, Division 1 Groups A, B, C, and D
|
 |
 |
 |
 |
 |
 |
| Solaris Multigas Detector |
 |
Model RP Calibration Check Kits |
 |
 |
Brand: MSA
Model No: 10048148
Packing: 1 set/case |
 |
 |
Brand: MSA
Model No: 477149
Packing: 1 set/case |
 |
- Affordable, durable, reliable, easy-to-use portable instruments for detecting the presence of O2, H2S, CO and combustible gas
- World class triple alarm system with 100+ dB audible alarm, multiple high-intensity visual alarm and strong vibrating alarm
- Superior display feature
- Lightweight – Under 8 oz, compact size makes easy to wear
- Long-life battery – rechargeable lithium ion battery provides 14 hours of continuous run time
|
 |
- Consist of a regulating valve which includes a gauge to measure container pressure, an adapter hose, sensor adapter (where applicable), instructions, and a case fitted with room for two Model RP cylinders of calibration check-gas
- Check-gas cylinders sold separately
|
 |
 |
 |
 |
 |
 |
| Model RP Calibration Cylinder |
 |
Econo-Cal Calibration Cylinder |
 |
 |
Brand: MSA
Model No: 804770
Packing: 1 set/case |
 |
 |
Brand: MSA
Model No: 711058
Packing: 1 set/case |
 |
- Model RP contents: 500 psig, approximately 58 liters at atmospheric pressure
- Combination of 1.45% methane, 15% oxygen, 300ppm of carbon monoxide, 10 ppm of hydrogen sulphide
- Size: 133/4" x 3"
- Weight: 1 lb 11 oz
- Material: Aluminum
|
 |
- Econo-cal contents: Pressure 500 psig, approximately 34 liters at atmospheric pressure
- Combination of 1.45% methane, 15% oxygen, 300ppm of carbon monoxide, 10 ppm of hydrogen sulphide
- Size: 133/4" x 3"
- Weight: 1 lb 1 oz
- Material: Aluminum
|
 |
|
|